FIX PLUS 5 compression sprayer
MESTO FIX PLUS compression sprayer 5 liters. Compression sprayer for use in the trade sector. Suitable for spraying forming oil and other sprayable construction chemicals. The plastic tank has a fill capacity of 5 l, can be carried on the side and has a large pressure reservoir, which helps to avoid frequent re-pumping. The FIX PLUS is equipped with a professional pump with ergonomic pump handle, a 50 cm long and 360° rotatable brass spray wand with special flat jet nozzle 80-01E made of brass and a 2 m long transparent oil-resistant hose. FPM seals provide excellent resistance to many construction chemicals. Spray wands and extension wands can be stored optimally on the device. The easy-to-clean integrated dirt filter simply adds to the comprehensive set of equipment for the FIX PLUS.
Düsenanwendung | for release agents which require fine distribution in the construction industry |
---|---|
Product class | Comfort ** |
EAN | 4000903323127 |
Article type | Compression sprayer |
Fill capacity | 5 l |
Total contents | 7 l |
Max. operating pressure | 3 bar/44 psi/0.3 MPa |
Weight | 1,7 Kg |
Tank material | Plastic |
Portability | on the side |
Nozzle type | Flat jet rectangular distribution, Spray nozzle, Filter |
Spray wand material | Plastic |
Shut-off valve material | Plastic |
Shut-off valve connection | D8 |
Shut-off valve characteristics | with safety interlock |
Hose length | 200 cm |
Hose diameter | D8 |
Safety valve | ja |
Pressure gauge | Piston pressure gauge |
Compressed air filler valve | can be retrofitted |
Device equipment | Ergonomic shut-off valve helps protect your wrist., Safety interlock on the shut-off valve prevents unintentional spraying., Extra large filler opening with integrated filling funnel for simple filling and emptying without any spillage., Base with foot ring for a sturdy foothold when pumping., Spray wand and extension wand holders for space-saving and safe storage., Carrying strap for carrying at the side over the shoulder., Embossed level scale to monitor the level at all times., oil-resistant hose., Nozzle for liquids requiring fine distribution., Flat jet nozzle for area spraying., Hose coupling with filter to prevent clogging of the nozzle. |
Nozzle material | Plastic |
Nozzle material | Plastic |
Select the desired download.
Type | Description | File extension | File size |
---|
If you miss a download, please write us via our contact form.
Devices may not be used for spraying plant protection liquids.
Only trained, healthy and rested people may work with the device. You should not be under the influence of alcohol, drugs or medication.
Children and adolescents must not use the device. Keep the spraying devices safe from access to children.
Take precautions to prevent hazardous substances from being misused.
→ Accident risk!
Keep bystanders away during spraying.
Never spray on people, animals, electrical devices and lines, into the wind, or into bodies of water.
→ Risk of injury!
Wear appropriate protective clothing, goggles and respiratory protection in line with the applicable national regulations when working with hazardous substances.
Avoid ignition sources in the environment.
Do not allow the device to remain under pressure and/or exposed directly to sunlight. Make certain the device is not heated beyond the maximum operating temperature. (→Table 1).
Protect the device from frost and ammonia.
Never blow through the nozzles or valves with your mouth.
→ Risk of poisoning!
There is a risk of slipping or tripping on smooth or wet surfaces, snow, ice, on slopes and on uneven terrain.
Repairs and modifications to the device are not permitted. Have damaged parts or parts that do not work properly repaired immediately by our customer service department or by service partners authorized by us.
The effect of the safety valve must not be bypassed or made inoperative.
→ Explosion hazard!
Use only original spare and accessory parts. We cannot assume any liability resulting from the use of third-party parts.
When pumping, always observe the pressure gauge to ensure the maximum
spraying pressure is not exceeded (→ Table 1).
All excess pressure must be released from the device before filling, after use, before carrying out maintenance work, on work breaks, and before placing it in storage.
Points to note when transporting the device: Transport the device in such a way that it is protected against damage and tipping. All excess pressure must be released from the device.
→ Explosion hazard!
If the device leaks at the container, immediately depressurise the device and put it out of operation!
→ Risk of explosion!